<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-05 14-25-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.70 MHz 4/5, 28 dBuV INFO
Pilot RDS Phase Difference
0.0 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
14 kHz 15 kHz 5454 0,0367
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
1,8 dBr 3,21 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INFO " F206 0 (No PTY) 0 0 0 0 14:25, 5.09.2024
RT
"FRANCEINFO ET VOUS - FRANCEINFO : L'INFO JUSTE. "
AF EON
103.1, 105.5, 105.7 MHz F207, F202, F201
FM Scope Station: 105.70 MHz, signal: 4/5 (28 dBuV) Max at: 15 kHz MIN: 14 kHz % above 75 kHz: 0,0367 Acquired: 2024/09/05 14:24:54 Total samples: 5454 Equivalent time: 0:04:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 4,8 dBr MIN: 1,8 dBr AVE: 3,21 dBr % above 11,2 dBr: 0,0 Last value: 1,9 dBr (2024/09/05 14:24:53) Station: 105.70 MHz, signal: 4/5 (28 dBuV) 14:12 14:14 14:16 14:18 14:20 14:22 14:24 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality